Home>Mass Spectrometry
Mass Spectrometry
Model | Max Output | introduction | |
---|---|---|---|
Voltage(KV) | Power(W) | ||
|
0.1KV 0.2KV 1KV 1.25KV 1.5KV 2KV |
0.5W 1W 2W |
1.Models from 0.1KV to 2kV, 0.5W to 2W 2. Low ripple and noise <5mV p-p 3. high stablity 0.001% per hour 4. low temperature coefficient 0.001%/ ℃ 5. Arc and short-circuit protection 6. External potentiometer or external voltage to set 7. small size,printed circuit board mounting 8. positive and negative output 9. six-sides shielding and has strong anti-interference 10. OEM customization available |
|
0.1KV 0.2KV 0.3KV 0.4KV 0.5KV 0.6KV 0.8KV 1KV 1.1KV 1.25KV 1.5KV 2KV |
0.5W 1W 2W |
1.Models from 0.1KV to 2kV, 0.5W to 2W 2. Low ripple and noise <5mV p-p 3. high stablity 0.001% per hour 4. low temperature coefficient 0.001%/ ℃ 5. Arc and short-circuit protection 6. External potentiometer or external voltage to set 7. small size,printed circuit board mounting 8. positive and negative output 9. six-sides shielding and has strong anti-interference 10. OEM customization available |
|
0.1KV 0.2KV 0.3KV 0.4KV 0.5KV 0.6KV 0.8KV 1KV 1.1KV 1.25KV 1.5KV 2KV 3KV |
0.5W 1W 2W |
1.Models from 0.1KV to 3kV, 0.5W to 2W 2. Low ripple and noise <5mV p-p 3. high stablity 0.001% per hour 4. low temperature coefficient 0.001%/ ℃ 5. Arc and short-circuit protection 6. External potentiometer or external voltage to set 7. small size,printed circuit board mounting 8. positive and negative output 9. six-sides shielding and has strong anti-interference 10. OEM customization available |
|
0.1KV 0.2KV 0.3KV 0.4KV 0.5KV 0.6KV 0.8KV 1KV 1.1KV 1.25KV 1.5KV 2KV |
0.5W 1W 2W |
1.Models from 0.1KV to 2kV, 0.5W to 2W 2. Low ripple and noise <5mV p-p 3. high stablity 0.001% per hour 4. low temperature coefficient 0.001%/ ℃ 5. Arc and short-circuit protection 6. External potentiometer or external voltage to set 7. small size,printed circuit board mounting 8. positive and negative output 9. six-sides shielding and has strong anti-interference 10. OEM customization available |
|
3KV 4KV 5KV 6KV 6.5KV 7KV 8KV 9KV 10KV |
0.5W 1W 2W |
1.Models from 3KV to 10kV, 0.5W to 2W 2. Low ripple and noise <10ppm 3. high stablity 0.001% per hour 4. low temperature coefficient 25ppm/ ℃ 5. Arc and short-circuit protection 6. External potentiometer or external voltage to set 7. small size,printed circuit board mounting 8. positive and negative output 9. six-sides shielding and has strong anti-interference 10. OEM customization available |
|
0.05KV 0.1KV 0.2KV 0.3KV 0.4KV 0.5KV 0.6KV 0.8KV 1KV 1.25KV 1.5KV 2KV |
3W 4W 5W |
1.Models from 0.1KV to 2kV, 3W to 5W 2. Low ripple and noise <10ppm 3. high stablity 0.001% per hour 4. low temperature coefficient 10ppm/ ℃ 5. Arc and short-circuit protection 6. External potentiometer or external voltage to set 7. small size,printed circuit board mounting 8. positive and negative output 9. six-sides shielding and has strong anti-interference 10. OEM customization available |
|
0.3KV 0.5KV 1KV 1.5KV 2KV 2.5KV 3KV 4KV 5KV 6KV 8KV 10KV |
1W 2W 3W 4W 5W |
1.Models from 0.3KV to 10kV, 2W to 6W 2. Low ripple and noise <10ppm 3. high stablity 0.001% per hour 4. low temperature coefficient 10ppm/ ℃ 5. Arc and short-circuit protection 6. External potentiometer or external voltage to set 7. small size,printed circuit board mounting 8. positive and negative output 9. six-sides shielding and has strong anti-interference 10. OEM customization available |
|
0.3KV 0.5KV 1KV 1.5KV 2KV 2.5KV 3KV |
1W 2W 3W 4W 5W |
1.Models from 0.3KV to 3kV, 1W to 5W 2. Low ripple and noise <10ppm 3. high stablity 0.001% per hour 4. low temperature coefficient 10ppm/ ℃ 5. Arc and short-circuit protection 6. External potentiometer or external voltage to set 7. small size,printed circuit board mounting 8. positive and negative output 9. six-sides shielding and has strong anti-interference 10. OEM customization available |
|
0.05KV 0.1KV 0.15KV 0.2KV 0.25KV 0.5KV 1KV 2KV 3KV 4KV 5KV 6KV |
6W 10W 20W 30W |
1. Models from 0.05KV to 6kV, 6W to 30W 2. Ultra low output ripple and noise 0.001%p-p 3. Ultra high stability 0.001% per hour 4. Ultra low temperature coefficient 0.001% / ℃ 5. Arc and short-circuit protection 6. External voltage to set 7. Compact size,pcb mounting 8. Positive or negative output 9. Six-sided shielding for anti-interference 10. OEM customization available |
|
0.5KV 1KV 1.5KV 2KV 3KV 4KV 5KV 7.5KV 10KV |
2W 2.5W 3W 4W 5W 6W 8W 10W |
1. Models from1kV to 30kV, 10W MAX 2. Low output ripple and noise < 2mV P-P 3. High stability 0.001% per hour 4. Low temperature coefficient 0.001%/℃ 5. Low temperature coefficient of 25 ppm per degree Celsius 6. Arc and Short Circuit Protected 7. External potentiometer or external control voltage to set. 8. Optional RS-232, RS-485 control, address can be set and search 9. Positive or negative output 10. Small size, Low noise, 6 -sided metal shielding 11. OEM customization available 12.CE certification |
|
1KV 2KV 2.5KV 3KV 5KV 10KV 15KV 20KV 30KV |
5W 10W 20W |
1. Models from1kV to 30kV, 5W, 10W, 20W 2. Low output ripple and noise <0.001% P-P 3. High stability 25ppm per hour 4. Low temperature coefficient 25ppm/℃ 5. Low temperature coefficient of 25 ppm per degree Celsius, optionally 10 ppm. 6. Arc and Short Circuit Protected 7. External potentiometer or external control voltage to set. 8. Optional RS-232, RS-485 control, address can be set and research 9. Positive or negative output 10. Small size, Low noise , six -sided metal shielding 11. CE certification |
|
1KV 2KV 2.5KV 3KV 5KV 10KV 15KV 20KV 30KV |
5W 10W 20W |
1. Ideal for MASS 2. Input DC24V 3. Models from1kV to 30kV, 5W, 10W, 20W 4. High stability 10ppm/hour,20ppm/8hour,100ppm/1000hour 5. High stability 10ppm/hour,20ppm/8hour,100ppm/1000hour 6. Low output ripple and noise less than 5ppm 7. Arc and Short Circuit Protected 8. External potentiometer or external control voltage to set. 9. Optional RS-232, RS-485 control, address can be set and research 10. Small size, Low noise,6 -sided metal shielding 11. Positive polarity or negative polarity output, OEM customisation available 12. CE certification |
|
1KV 2KV 2.5KV 3KV 5KV 10KV 15KV 20KV 30KV |
5W 10W 20W |
1. Ideal for SEM and Mass spectrometry 2. Models from1kV to 30kV, 5W, 10W, 20W 3. Low output ripple and noise less than 2ppm 4. High stability 10ppm/hour,20ppm/8hour,100ppm/1000hour 5. Low temperature coefficient 10ppm/℃ 6. Arc and Short Circuit Protected 7. External potentiometer or external control voltage to set. 8. Ethernet,RS-232 Standard,RS-485 optionl, address can be set and research 9. Positive or negative output 10. Small size, Low noise,6 -sided metal shielding 11. OEM customized available. |
|
0.6KV 1.2KV 2KV 3KV 5KV 7.5KV 10KV 12KV 15KV 20KV 25KV 30KV |
6W 9W 15W 30W 60W 75W 100W |
1. Models from3kV to 30kV, 6W to 100W 2. Low output ripple and noise less than 0.1% P-P 3. High stability 0.01% /8 hours 4. Low temperature coefficient 25PPM/ ℃ 5. Arc and Short Circuit Protected 6. External potentiometer or external control voltage to set. 7. Optional RS-232, RS-485 control, address can be set and research 8. Positive or negative output 9. Small size, Low noise , 6 -sided metal shielding 10. OEM customization available 11. Input DC 24V 12.CE certification |
|
1KV 3KV 5KV 6KV 8KV |
0.5W 1W 2W 4W 5W 6W 8W 10W |
1. Output voltage up to ±8KV, power 0.5W-10W 2. Optional RS-232, RS-485 control |
|
1KV 5KV 8KV 10KV 15KV 18KV 20KV |
2W 5W 8W 10W |
1. The output voltage is up to ±20KV, and the power is 2W-10W |
|
1KV 5KV 10KV 15KV 20KV 25KV 30KV |
5W 6W 8W 10W |
1. Output voltage up to ±30KV, power 5W-10W |
|
1KV 5KV 10KV 15KV 20KV 25KV 30KV |
5W 6W 8W 10W |
1. Reliable packaging, long-term corona-free operation |
|
75KV |
0W |
Receptacle cb100c3, 3 pins, rated for up to 100 kvdc. |
|
80KV 120KV 200KV 300KV |
60W |
Transmission Electron Microscope Power Supplies OEM Customation availble Voltage: 80kv,120kv,200kv,300kv Current: 100-300uA |
|
2KV |
3W |
1.Output voltage ±300V-±2KV 2. Reverse speed: 50V/us 3. In-phase proportional amplifier 4.four-quadrant output driving load 5.closed loop system, low noise, high precision 6. With short circuit protection 7.can be used as DC power supply |
|
0.05KV 0.1KV 0.2KV 0.3KV 0.4KV 0.5KV 0.6KV 0.8KV 1KV 1.25KV 1.5KV 2KV |
1W 2W |
1.Output voltage±50v~±2kv 4.Fast reversing, slewing & settling 7.Temperature coefficient 10ppm/℃ 8. Voltage regulatioLoad regulation 0.001% 10. Arc & short circuit protection 11.OEMn 0.001% 9. customization available |
|
5KV |
100W |
1.Output voltage: 0 to ±5 kV DC or peak AC 7. Dynamically adjust to optimize AC response for various load parameters 8. Local and remote high voltage on/off function, short circuit protection 9. Low output noise, closed-loop system guarantees high accuracy 10. Utilizes complete solid-state design and maintenance-free design 11. Prevents overvoltage and overcurrent conditions generated by active loads 12. Drives capacitive loads through four-quadrant output |
|
10KV |
100W |
1. Output voltage: 0 to ±10kVDC or peak AC 2. Output current: 0 to ±10 mA DC or 40mA peak AC for 1 ms 3. Slew rate: greater than 150 V/μs 4. Large signal bandwidth: DC to greater than 15kHz (-3dB) 5. DC voltage gain: 500 V/V 6. OEM customization available 7. Dynamic adjustment to optimize AC response for various load parameters 8. Local and remote high voltage on/off function, short circuit protection 9. Low output noise, closed-loop system ensures high precision 10. Take advantage of the complete solid-state design and maintenance-free design 11. Protection against overvoltage and overcurrent conditions generated by active loads 12. Drive capacitive loads with four-quadrant output |
|
2KV |
400W |
1. Output voltage: 0 to ±2 kV DC or peak AC 2. Output current: 0 to ±200 mA DC or ±400 mA peak AC 3. Slew rate: greater than 750 V / μs 4. Large signal bandwidth: DC to greater than 60kHz (-3dB) 5. DC voltage gain: 200 V / V 6. OEM cutomization available 7. Dynamically adjust to optimize AC response for various load parameters 8. Local and remote high voltage on/off function, short circuit protection 9. Low output noise, closed-loop system guarantees high accuracy 10. Utilizes complete solid-state design and maintenance-free design 11. Prevents overvoltage and overcurrent conditions generated by active loads 12. Drives capacitive loads through four-quadrant output |
|
5KV |
400W |
1. Output voltage: 0 to ±5 kV DC or peak AC 2. Output current: 0 to ±80 mA DC peak AC 3. Slew rate: greater than 1000 V / μs 4. Large signal bandwidth: DC to greater than60kHz (-3dB) 5. DC voltage gain: 500 V / V 6. OEM cutomization available 7. Dynamically adjust to optimize AC response for various load parameters 8. Local and remote high voltage on/off function, short circuit protection 9. Low output noise, closed-loop system guarantees high accuracy 10. Utilizes complete solid-state design and maintenance-free design 11. Prevents overvoltage and overcurrent conditions generated by active loads 12. Drives capacitive loads through four-quadrant output |
|
7.5KV |
400W |
1. Output voltage: 0 to ±7.5 kV DC or peak AC 2. Output current: 0 to ±50 mA DC or peak AC 3. Slew rate: > 1000 V / μs 4. Large signal bandwidth: DC to greater than 15kHz(-3dB) 5. DC voltage gain: 750 V / V 6. OEM customization available 7. Dynamically adjust to optimize AC response for various load parameters 8. Local and remote high voltage on/off function, short circuit protection 9. Low output noise, closed-loop system guarantees high accuracy 10. Utilizes complete solid-state design and maintenance-free design 11. Prevents overvoltage and overcurrent conditions generated by active loads 12. Drives capacitive loads through four-quadrant output |
|
10KV |
400W |
1.Output voltage: 0 to ±10 kV DC or peak AC 7. Dynamically adjust to optimize AC response for various load parameters 8. Local and remote high voltage on/off function, short circuit protection 9. Low output noise, closed-loop system guarantees high accuracy 10. Utilizes complete solid-state design and maintenance-free design 11. Prevents overvoltage and overcurrent conditions generated by active loads 12. Drives capacitive loads through four-quadrant output |
|
20KV |
400W |
1. Output voltage: 0 to ±20 kV DC or peak AC 5. DC voltage gain: 2000 V / V 7. Dynamically adjust to optimize AC response for various load parameters 8. Local and remote high voltage on/off function, short circuit protection 9. Low output noise, closed-loop system guarantees high accuracy 10. Utilizes complete solid-state design and maintenance-free design 11. Prevents overvoltage and overcurrent conditions generated by active loads 12. Drives capacitive loads through four-quadrant output |
|
1KV 2KV 2.5KV 3KV 5KV 10KV 15KV 20KV 30KV |
5W 10W 20W |
1. Suitable for electron microscope, mass spectrometer MASS 2. Input 220Vac, single phase 3. Output voltage up to 30KV, output power 5W, 10W, 20W 4. Low output ripple and noise <2ppm 5. High stability 50ppm/h, 100ppm/8h, 500ppm/1000h 6. Low temperature coefficient 25ppm/℃ 7. Standard RS-485 control,address can be set and research 8. Suspended ground, six-sided shielding 9. Ooutput voltage channels 512 Max. 10. Each channel can be used independently . 11.Panel control or computer remote control 12.Arc and short circuit protection. 13.Positive or negative output,OEM customization available. |
|
1KV 2KV 2.5KV 3KV 5KV 10KV 15KV 20KV 30KV |
5W 10W 20W |
1. AC/DC, AC220V power supply 2. The maximum output voltage of each channel is 1-30KV, and the maximum output power of each channel is 20W 3. Ripple voltage: 0.001% P-P 4. Temperature coefficient: ≤25ppm/℃ (customizable ≤10ppm/℃) 5. Stability: 10ppm/h less than 100ppm/8h 6.8-channel independent output, independent control, independent display 7. The output voltage and current of each channel can be the same or different 8. Standard RS-485 computer remote control 9. Blank front panel, computer remote control 10. Over voltage, arcing and output short circuit protection 11. Voltage & current programming 12. OEM customization available |
|
1KV 2KV 2.5KV 3KV 5KV 10KV 15KV 20KV 30KV |
5W 10W 20W |
1. AC/DC , AC220V power supply 2. The output voltage is up to 30KV,output power is 20W MAX 3. Ripple and noise <0.001% p-p(Lower ripple can be customized) 4. Temperature coefficient: ≤25ppm/℃ 5. Stability: less than 10ppm/1h after starting for half an hour, less than 100ppm/8 h 6. 8 independent outputs, independent control, independent display 7. The output voltage and current of each channel can be the same or different 8. Standard RS-485 computer remote control 9. Front panel controls and displays,computer remote control 10. Over voltage, arcing and output short circuit protection 11.Voltage and current regulation function 12. OEM customization available |
|
1KV 2KV 2.5KV 3KV 5KV 10KV 15KV 20KV 30KV |
5W 10W 20W |
1. Suitable for electron microscope, mass spectrometer MASS 2. Input 220Vac, single phase 3. Output voltage up to 30KV, output power 5W, 10W, 20W 4. Low output ripple and noise <2ppm 5. High stability 10ppm/H, 20ppm/8h, 100ppm/1000h 6. Low temperature coefficient 10ppm/℃ 7. Standard RS-485 control,address can be set and research 8. Suspended ground, six-sided shielding 9. Ooutput voltage channels 512 Max. 10. Each channel can be used independently . 11.Panel control or computer remote control 12.Arc and short circuit protection. 13.Positive or negative output,OEM customization available. |
|
40KV |
600W |
1. Output voltage: 0 to ±40 kV DC or peak AC 2. Output current: 0 to ±15 mA DC or peak AC 3. Conversion rate: greater than 350 V / μs 4. Large signal bandwidth: DC to greater than 2.5kHz (-3dB) 5. DC voltage gain: 4000 V / V 6. Customers can customize by OEM 7. Dynamic adjustment to optimize AC response for various load parameters 8. Local and remote high voltage on/off function, short circuit protection 9. Low output noise, closed loop system to ensure high accuracy 10. Utilize complete solid-state design and maintenance-free design 11. Prevent over-voltage and over-current conditions generated by active loads 12. Drive capacitive load through four-quadrant output |
|
1KV 2KV 3KV 6KV 8KV 10KV 15KV 20KV 30KV 40KV 50KV 60KV 70KV |
10W 30W 60W 100W 150W 300W 600W 1200W 2000W |
1. AC/DC ,The output voltage is up to70KV,output power is 2000W MAX 2. Ripple and noise <0.1% p-p(Lower ripple can be customized)Temperature coefficient: ≤25ppm/℃ 3. Stability: less than 100ppm every 1 hour after starting for half an hour, less than 500ppm every 8 hours 4.10 independent outputs, independent control, independent display 5. Standard RS-485 computer remote control 6. It can be controlled and displayed on the front panel, and can be remotely controlled by a computer 7. AC220V power supply 8. Over voltage, arcing and output short circuit protection 9. Voltage and current regulation function 10. OEM customization available 11. High stability, low ripple |
|
1KV 2KV 2.5KV 3KV 5KV 10KV 15KV 20KV 30KV |
5W 10W 20W |
1. Suitable for electron microscope, mass spectrometer MASS 2. Input 220Vac, single phase 3. Output voltage up to 30KV, output power 5W, 10W, 20W 4. Low output ripple and noise <2ppm 5. High stability 50ppm/h, 100ppm/8h, 500ppm/1000h 6. Low temperature coefficient 25ppm/℃ 7. Standard RS-485 control,address can be set and research 8. Suspended ground, six-sided shielding 9. Ooutput voltage channels 512 Max. 10. Each channel can be used independently . 11.Panel control or computer remote control 12.Arc and short circuit protection. 13.Positive or negative output,OEM customization available. |
|
10KV 20KV 30KV 40KV |
0W |
1. Excellent moisture-proof, anti-oxidation and anti-radiation properties 2. Excellent flexibility, can be bent at will, easy to install 3. Suitable for use under ambient temperature of +180℃~-60℃ 4. Wire core: 22Awg (customization), material tinned copper wire 5.Insulation layer: silicone rubber 6.Color: red, white, black |
|
2KV |
1.5W |
1. DC/DC output voltage 0-2KV, output power 1.5W 2. low ripple: 5mVp-p 3. High stability 0.02%/h 4. low temperature coefficient 70ppm/°C 5. Arc and short circuit protection 6. External potentiometer or external control voltage feedforward 7. Small size, printed circuit board mounting 8. six-sides shielding and has strong anti-interference 9. OEM customisation available |
|
1KV 2KV 3KV 6KV 8KV 10KV 15KV 20KV 30KV 40KV 50KV 60KV 70KV 80KV 100KV 120KV 130KV 150KV 200KV 250KV 300KV |
60W 180W 600W 1200W 2000W |
1. The maximum output voltage of AC/DC can be selected from 1KV-300KV, the maximum power is 2000W 2. Ripple voltage: ≤10ppm Temperature coefficient: ≤10ppm/℃ 3. Stability: ≤100ppm for 8 hours in a certain environment 4. Multiple models are available 7. Over temperature, over voltage, over current, arc and output short circuit protection 8. Voltage and current regulation function 9. Local or remote control 10. Security interlock function 11. OEM customization available 12. Standard network port, RS-232, RS-485 control |